Model # Description (Click to see drawing)
13-002.100.1 1 kOhm, measuring range 100 mm, wire wound, plug connection (axial), dimensions according to dwg. no. 13-002 ,Transducer 13-002Ec.pdf
13-002.100.2 2 kOhm, measuring range 100 mm, wire wound, plug connection (axial), dimensions according to dwg. no. 13-002 ,Transducer 13-002Ec.pdf
13-002.100.5 5 kOhm, measuring range 100 mm, wire wound, plug connection (axial), dimensions according to dwg. no. 13-002 ,Transducer 13-002Ec.pdf
13-002.150.1 1 kOhm, measuring range 150 mm, wire wound, plug connection (axial), dimensions according to dwg. no. 13-002 ,Transducer 13-002Ec.pdf
13-002.150.5 5 kOhm, measuring range 150 mm, wire wound, plug connection (axial), dimensions according to dwg. no. 13-002 ,Transducer 13-002Ec.pdf
13-002.25.1 1 kOhm, measuring range 25 mm, wire wound, plug connection (axial), dimensions according to dwg. no. 13-002 ,Transducer 13-002Ec.pdf
13-002.50.1 1 kOhm, measuring range 50 mm, wire wound, plug connection (axial), dimensions according to dwg. no. 13-002 ,Transducer 13-002Ec.pdf
13-003.100.1 1 kOhm, measuring range 100 mm, wire wound, cable connection (axial), dimensions according to dwg. no. 13-003 ,Transducer
13-003.100.2 2 kOhm, measuring range 100 mm, wire wound, cable connection (axial), dimensions according to dwg. no. 13-003 ,Transducer
13-003.100.5 5 kOhm, measuring range 100 mm, wire wound, cable connection (axial), dimensions according to dwg. no. 13-003 ,Transducer
13-003.150.1 1 kOhm, measuring range 150 mm, wire wound, cable connection (axial), dimensions according to dwg. no.13-003 ,Transducer
13-003.150.2 2 kOhm, measuring range 150 mm, wire wound, cable connection (axial), dimensions according to dwg. no. 13-003 ,Transducer
13-003.150.5 5 kOhm, measuring range 150 mm, wire wound, cable connection (axial), dimensions according to dwg. no. 13-003 ,Transducer
13-003.25.1 1 kOhm, measuring range 25 mm, wire wound, cable connection (axial), dimensions according to dwg. no. 13-003 ,Transducer
13-003.25.5 5 kOhm, measuring range 25 mm, wire wound, cable connection (axial), dimensions according to dwg. no. 13-003 ,Transducer
13-003.50.1 1 kOhm, measuring range 50 mm, wire wound, cable connection (axial), dimensions according to dwg. no. 13-003 ,Transducer
13-003.50.2 2 kOhm, measuring range 50 mm, wire wound, cable connection (axial), dimensions according to dwg. no. 13-003 ,Transducer
13-004.100.1 1 kOhm, measuring range 100 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 13-004 ,Transducer 13-004Eb.pdf
13-004.100.2 2 kOhm, measuring range 100 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 13-004 ,Transducer  13-004Eb.pdf
13-004.100.5 5 kOhm, measuring range 100 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 13-004 ,Transducer 13-004Eb.pdf
13-004.150.2 2 kOhm, measuring range 150 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 13-004 ,Transducer 13-004Eb.pdf
13-004.150.5 5 kOhm, measuring range 150 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 13-004 ,Transducer 13-004Eb.pdf
13-004.25.5 5 kOhm, measuring range 25 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 13-004 ,Transducer 13-004Eb.pdf
13-004.50.1 1 kOhm, measuring range 50 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 13-004 ,Transducer 13-004Eb.pdf
13-004.50.2 2 kOhm, measuring range 50 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 13-004 ,Transducer 13-004Eb.pdf
13-004.50.5 5 kOhm, measuring range 50 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 13-004 ,Transducer 13-004Eb.pdf
13-007.100.1 1 kOhm, measuring range 100mm, wire wound, ball joints on both sides, plug connection (lateral), dimensions according to dwg. no. 13-007 ,Transducer 13-007E.pdf
13-007.100.2 2 kOhm, measuring range 100 mm, wire wound, ball joints on both sides, plug connection (lateral), dimensions according to dwg. no. 13-007 ,Transducer 13-007E.pdf
13-007.100.5 5 kOhm, measuring range 100 mm, wire wound, ball joints on both sides, plug connection (lateral), dimensions according to dwg. no. 13-007 ,Transducer 13-007E.pdf
13-007.150.1 1 kOhm, measuring range 150mm, wire wound, ball joints on both sides, plug connection (lateral), dimensions according to dwg. no. 13-007 ,Transducer 13-007E.pdf
13-007.150.2 2 kOhm, measuring range 150mm, wire wound, ball joints on both sides, plug connection (lateral), dimensions according to dwg. no. 13-007 ,Transducer 13-007E.pdf
13-007.150.5 5 kOhm, measuring range 150 mm, wire wound, ball joints on both sides, plug connection (lateral), dimensions according to dwg. no. 13-007 ,Transducer 13-007E.pdf
13-007.25.1 1 kOhm, measuring range 25 mm, wire wound, ball joints on both sides, plug connection (lateral), dimensions according to dwg. no. 13-007 ,Transducer 13-007E.pdf
13-007.50.1 1 kOhm, measuring range 50 mm, wire wound, ball joints on both sides, plug connection (lateral), dimensions according to dwg. no. 13-007 ,Transducer 13-007E.pdf
13-007.50.2 2 kOhm, measuring range 50mm, wire wound, ball joints on both sides, plug connection (lateral), dimensions according to dwg. no. 13-007 ,Transducer 13-007E.pdf
13-007.50.5 5 kOhm, measuring range 50mm, wire wound, ball joints on both sides, plug connection (lateral), dimensions according to dwg. no. 13-007 ,Transducer 13-007E.pdf
15-001 5 kOhm, measuring range 25 mm, conductive plastic, stranded wire connection, dimensions according to dwg. no. 15-001 ,Transducer 15-001Ef.pdf
15-022 5 kOhm, measuring range 25 mm, conductive plastic, with return spring, stranded wire connection, dimensions according to dwg. no. 15-022 ,Transducer 15-022E.pdf
16-001.100.10 10 kOhm, measuring range 100 mm, conductive plastic, stranded wire connection, dimensions according to dwg. no. 16-001 ,Transducer 16-001Ea.pdf
16-001.150.1 1 kOhm, measuring range 150 mm, conductive plastic, stranded wire connection, dimensions according to dwg. no. 16-001 ,Transducer 16-001Ea.pdf
16-001.25.5 5 kOhm, measuring range 25 mm, conductive plastic, stranded wire connection, dimensions according to dwg. no. 16-001 ,Transducer 16-001Ea.pdf
16-001.50.5 5 kOhm, measuring range 50 mm, conductive plastic, stranded wire connection, dimensions according to dwg. no. 16-001 ,Transducer 16-001Ea.pdf
22-013.100.5 5 kOhm, measuring range 100 mm, conductive plastic, cable connection (axial), dimensions according to dwg. no. 22-013 ,Transducer 22-013Ea.pdf
22-013.150.5 5 kOhm, measuring range 150 mm, conductive plastic, cable connection (axial), dimensions according to dwg. no. 22-013 ,Transducer 22-013Ea.pdf
22-013.25.1 1 kOhm, measuring range 25 mm, conductive plastic, cable connection (axial), dimensions according to dwg. no. 22-013 ,Transducer 22-013Ea.pdf
22-013.50.5 5 kOhm, measuring range 50 mm, conductive plastic, cable connection (axial), dimensions according to dwg. no. 22-013 ,Transducer 22-013Ea.pdf
22-019.100.5 5 kOhm, measuring range 100 mm, conductive plastic, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 22-019 ,Transducer 22-019Ea.pdf
22-019.150.5 5 kOhm, measuring range 150 mm, conductive plastic, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 22-019 ,Transducer 22-019Ea.pdf
22-019.25.1 1 kOhm, measuring range 25 mm, conductive plastic, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 22-019 ,Transducer 22-019Ea.pdf
22-019.50.5 5 kOhm, measuring range 50 mm, conductive plastic, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 22-019 ,Transducer 22-019Ea.pdf
22-022.100.1 1 kOhm, measuring range 100 mm, wire wound, cable connection (axial), dimensions according to dwg. no. 22-022 ,Transducer 22-022Ea.pdf
22-023.100.1 1 kOhm, measuring range 100 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 22-023 ,Transducer 22-023E.pdf
22-023.100.5 5 kOhm, Messbereich 100 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 22-023 ,Transducer 22-023E.pdf
22-024.100.5 5 kOhm, measuring range 100 mm, conductive plastic, plug connection (lateral), incl. counter plug 13-4, dimensions according to dwg. no. 22-024 ,Transducer 22-024E.pdf
22-024.150.5 5 kOhm, measuring range 150 mm, conductive plastic, plug connection (lateral), incl. counter plug 13-4, dimensions according to dwg. no. 22-024 ,Transducer 22-024E.pdf
22-024.25.1 1 kOhm, measuring range 25 mm, conductive plastic, plug connection (lateral), incl. counter plug 13-4, dimensions according to dwg. no. 22-024 ,Transducer 22-024E.pdf
22-024.50.5 5 kOhm, measuring range 50 mm, conductive plastic, plug connection (lateral), incl. counter plug 13-4, dimensions according to dwg. no. 22-024 ,Transducer 22-024E.pdf
22-034.100.5 5 kOhm, measuring range 100 mm, conductive plastic, mounting thread M16x1, cable connection (axial), dimensions according to dwg. no. 22-034 ,Transducer 22-034E.pdf
22-034.150.5 5 kOhm, measuring range 150 mm, conductive plastic, mounting thread M16x1, cable connection (axial), dimensions according to dwg. no. 22-034 ,Transducer 22-034E.pdf
22-034.25.1 1 kOhm, measuring range 25 mm, conductive plastic, mounting thread M16x1, cable connection (axial), dimensions according to dwg. no. 22-034 ,Transducer 22-034E.pdf
22-061.50.5 5 kOhm, measuring range 50 mm, conductive plastic, plug connection (axial) with coupling socket KD 13-4, dimensions according to dwg. no. 22-061 ,Transducer 22-061E.pdf
28-001.100.5 5 kOhm, measuring range 100 mm, conductive plastic, cable connection (axial), dimensions according to dwg. no. 28-001 ,Transducer 28-001Eb.pdf
28-001.150.5 5 kOhm, measuring range 150 mm, conductive plastic, cable connection (axial), dimensions according to dwg. no. 28-001 ,Transducer 28-001Eb.pdf
28-001.25.1 1 kOhm, measuring range 25 mm, conductive plastic, cable connection (axial), dimensions according to dwg. no. 28-001 ,Transducer 28-001Eb.pdf
28-001.50.5 5 kOhm, measuring range 50 mm, conductive plastic, cable connection (axial), dimensions according to dwg. no. 28-001 ,Transducer 28-001Eb.pdf
28-012.100.1 1 kOhm, measuring range 100 mm, wire wound, cable connection (axial), dimensions according to dwg. no. 28-012 ,Transducer 28-012b.pdf
28-026.100.5 5 kOhm, measuring range 100 mm, wire wound, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 28-026 ,Transducer 28-026.pdf
28-028.25.1 1 kOhm, measuring range 25 mm, conductive plastic, with return spring, cable connection (lateral), dimensions according to dwg. no. 28-028 ,Transducer 28-028d.pdf
28-034.100.5 5 kOhm, measuring range 100 mm, conductive plastic, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 28-034 ,Transducer 28-034E.pdf
28-034.150.5 5 kOhm, measuring range 150 mm, conductive plastic, ball jonts on both sides, cable connection (lateral), dimension according to dwg. no. 28-034 ,Transducer 28-034E.pdf
28-034.25.1 1 kOhm, measuring range 25 mm, conductive plastic, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 28-034 ,Transducer 28-034E.pdf
28-034.50.5 5 kOhm, measurig range 50 mm, conductive plastic, ball joints on both sides, cable connection (lateral), dimensions according to dwg. no. 28-034 ,Transducer 28-034E.pdf
28-028.50 5 kOhm, measuring range 50 mm, conductive plastic, with return spring, cable connection (lateral), dimensions according to dwg. no. 28-028 ,Transducer 28-028Ee.pdf